High Efficiency & Energy Saving: Adopts low-loss silicon steel sheets and optimized electromagnetic design to cut motor losses and boost power density.
Customizable Power & Voltage: Rated power covers up to 250000kW with voltage options ranging from 3.3kV to 13.8kV to satisfy diverse industrial requirements.
Superior Insulation & Reliability: F-class insulation system with VPI vacuum pressure impregnation, paired with cast aluminum or copper bar rotors for stable operation and excellent moisture resistance.
Flexible Protection and Cooling: Available protection classes from IP23 to IP56 and cooling modes including IC01, IC611, IC81W, configurable to fit various working environments.
International Standard Compliance: Conforms to ISO9001, CCC, GB755 and IEC34-1 standards to guarantee quality and safety for global markets.
Wide Industrial Compatibility: Ideal for compressors, fans, pumps and high-inertia loads such as crushers and blowers in mining, petrochemical and other heavy industries.
User-Friendly Maintenance: Box-type structure grants easy access to internal components. Equipped with on-line oil filling and draining devices for maintenance without shutdown.
Rich Manufacturing Background: More than 70 years of production experience, annual output capacity of 8000 MW, products exported to over 40 countries worldwide.
| Attribute Item | Specification | Attribute Item | Specification |
|---|---|---|---|
| Customization | Available | Application | Industrial |
| Operating Speed | Constant Speed | Model NO. | Y400-4-450KW |
| Stator Phase | Three-Phase | Series Type | Y, Y2 Series Three-Phase Motor |
| Rotor Structure | Squirrel-Cage | Enclosure Type | Closed Type |
| Pole Number | 2-16p | Starting Mode | Direct On-Line Starting |
| Certifications | ISO9001, CCC | Rated Power | Up to 250000kW |
| Frequency | 50Hz, 60Hz | Voltage | 3.3kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV |
| Frame Size | 315-1120mm | Cooling Method | IC01 |
| Mounting Arrangement | IM1001 | Rotation Direction | CW / CCW |
| Duty | S1 | Insulation Class | F |
| Protection Class | IP23 | Ambient Temperature | -20℃ ~ 40℃ |
| Installation Location | Indoor / Outdoor | Bearing Brand | SKF |
| Space Heater | Included | Export Packing | Standard Seaworthy Packing |
| Brand | CHANGLI | Origin | China |
| HS Code | 8501530090 | Production Capacity | 500000 Units / Year |
Manufactured with premium raw materials and mature processing techniques, this motor features high efficiency, low vibration, stable operation and simple installation and servicing.
Its power ratings, electrical characteristics, mounting dimensions and tolerances comply with GB755 Rotating Electrical Machines Rating and Performance, IEC34-1 Rotating Electrical Machines Rating and Performance and relevant machinery industry standards.
Five enclosure protection grades are available: IP23, IP44, IP54, IP55 and IP56, complying with GB4942.1 and IEC34-5. IP23 motors can be converted to IP44 (pipe ventilation type) or IPW24 (weather protected type). Custom protection classes can be provided upon request.
Three standard cooling options are offered as per GB/T1993 and IEC34-6: IC01, IC611 and IC81W. Other cooling configurations are negotiable for special requirements.
The standard construction and mounting form is IMB3 (horizontal foot-mounted), following GB997 and IEC 34-7 for motor construction and mounting type codes.
Based on rotor type, protection class and cooling method, the whole series is divided into 8 sub-models as shown below:
| Model | Protection Class | Cooling Method | Squirrel Cage Rotor | Wound Rotor |
|---|---|---|---|---|
| Damp Proof | IP23 | IC01 | Y Series Motor | YR Series Motor |
| Weather Protected | IPW24 | IC01 | YQF Series Motor | YRQF Series Motor |
| Air-Water Cooled Enclosed | IP44, IP54, IP55, IP56 | IC81W | YKS Series Motor | YRKS Series Motor |
| Air-Air Cooled Enclosed | IP44, IP54, IP55, IP56 | IC611 | YKK Series Motor | YRKK Series Motor |
The technical data and overall installation dimensions of 10kV motors listed in this catalog can be adapted for 3kV, 10.5kV and 11kV variants of the same frame sizes.
Normal Operating Conditions:
The motor adopts internationally popular box construction. Frame and end shields are steel plate welded for high rigidity and lightweight design. After removing the protective cover or cooler, internal components are accessible for convenient installation and inspection.
The stator adopts external pressing structure. Stator windings use F-class insulation and corona-resistant materials, with reliable special binding for terminal fixation. The entire stator undergoes VPI vacuum pressure impregnation with F-class solventless varnish, delivering outstanding insulation, moisture resistance and shock resistance.
Squirrel cage rotors are mostly cast aluminum type with low failure rate for dependable operation. Copper bar squirrel cage rotors adopt advanced reliable welding technology and secure slot fastening. Wound rotors also use F-class insulation and VPI treatment.
Two bearing types are available: rolling bearing and sliding bearing, selected according to motor power and speed. Base bearing protection grade is IP44; bearing protection will be upgraded accordingly for higher motor enclosure grades.
Rolling bearing versions are equipped with on-line oil filling and draining devices, enabling lubricant replenishment and discharge without equipment shutdown using dedicated tools.
The main terminal box is sealed with IP54 protection. It is mounted on the right side facing the shaft end and can be rearranged to the left side on demand. Cable entry ports can be oriented upward, downward, left or right. Independent grounding terminals are fitted inside the box.
This starting guidance applies to loads with torque characteristics typical for pumps and fans.
Under above conditions, the motor allows two successive cold starts or one hot start. Restarts must wait for full natural stop. Any additional startup attempt requires a one-hour cooling interval.
If the converted inertia of driven machinery exceeds the listed load J value, frequent starting is required, or heavy-load startup is needed, please contact our engineering team for special design confirmation.
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
Frame Size: H355-1120
Rated Voltage: 3kV, 3.3kV, 5.5kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV
Pole Count: 2P,4P,6P,8P,10P,12P,14P,16P
Protection Grade: IP23, IPW24
Mounting Types: IMB3, IMB35, IMB5, IMV1 etc.
Power Range: Up to 25000kW
Frequency: 50Hz, 60Hz
Cooling Method: IC01
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
High Voltage Three Phase Squirrel Cage Induction Motor for Blower 450kW
Standard seaworthy export packing
Plywood case or fumigated wooden case
Suitable for long-distance sea transportation
In-process Inspection & Quality Control
All measuring instruments are calibrated annually. Full inspection is implemented for every component.
| Component | Inspection Items |
|---|---|
| Coil | 1. Raw material physical & chemical test2. Winding process inspection3. Winding dimension check |
| Iron Core | 1. Silicon steel sheet material test report2. Lamination burr and coating inspection3. Laminated core dimension verification |
| Frame | 1. Weldment conformity certificate2. Finishing dimension inspection |
| Rotor | 1. Core stacking inspection2. Conducting bar welding inspection3. End ring material, appearance, conductivity and dimension check4. Slot bar fastening inspection5. Outer diameter and overall dimension check6. Dynamic balancing correction |
| Shaft | 1. Raw material and annealing inspection2. Finishing dimension check |
| Stator | 1. Core compaction inspection2. Core length and segment length check3. Winding insertion inspection4. Iron loss test |
| Assembly | 1. Plain bearing dimension and surface quality check2. Air gap, stator-rotor center alignment, internal fan and baffle clearance check3. Internal cleaning inspection4. Shaft center height and mounting dimension verification |
| Final Test | 1. Routine test2. Type test |
Every motor undergoes full testing before delivery and can only be shipped after passing inspection. A test report will be supplied with each unit.
Winding three-phase DC resistance
Winding insulation resistance to earth
Winding high voltage withstand test
No-load current
No-load power
No-load loss
Three-phase no-load current unbalance
Locked rotor current
Locked rotor torque
Maximum torque
Rotation direction
Vibration: horizontal, vertical, axial
Noise
Full load input power
Full load current
Stator winding loss
Rotor winding loss
Iron loss
Mechanical loss
Stray loss
Full load slip
Stator winding temperature rise
Bearing temperature
Hot insulation resistance of winding
Overload test
Full load power factor
Efficiency
Standard warranty: 12 months after commissioning or 18 months after shipment, whichever comes first.
Extended warranty service is available upon request, contact us for details.