| Item | Specification | Item | Specification |
|---|---|---|---|
| Model NO. | Y710-4-3550KW | Number of Stator | Three-Phase |
| Series Type | Y, Y2 Series Three-Phase Motor | Rotor Structure | Squirrel-Cage |
| Enclosure Protection Type | Open Type | Pole Number | 2-12P |
| Starting Mode | Direct On-line Starting | Certifications | CCC, CE |
| Brand | Changli | Rated Power | Up to 250000kW |
| Frequency | 50Hz, 60Hz | Rated Voltage | 3.3kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV |
| Frame Size | 315-1120mm | Cooling Method | IC01 |
| Mounting Arrangement | IM1001 | Rotation Direction | CW / CCW |
| Duty Type | S1 | Insulation Class | F |
| Protection Degree | IP23 | Ambient Temperature | -20℃ ~ 40℃ |
| Installation Location | Indoor / Outdoor | Bearing Brand | SKF |
| Space Heater | Available | Export Packaging | Standard Seaworthy Packing |
| Trademark | CHANGLI | Origin | China |
| HS Code | 8501530090 | Annual Production Capacity | 500000 sets |
The Y series high voltage three-phase induction motor was independently developed and launched by our company based on introduced technology back in the 1980s, with more than 30 years of development history. In recent years, upgraded insulation materials, low-loss silicon steel sheets and continuous design optimization have effectively cut various internal losses and raised motor power capacity. Drawing on our 60 years of experience in high voltage induction motor design and manufacturing, we completed the latest round of optimization to satisfy domestic and industrial market requirements.
Test results verify that this motor series reaches or approaches global advanced levels in both technical and economic performance. Mass production has been realized, and the motors are exported to over 40 countries and regions across Europe, America, Africa, Hong Kong, Macao and other territories, winning consistent positive feedback from end users.
Manufactured with premium raw materials and mature production processes, this motor features high efficiency, energy saving, low vibration, stable operation, easy installation and convenient maintenance.
Its power ratings, electrical characteristics, mounting dimensions and tolerances comply with GB755 (Rotating electrical machines — Ratings and performance), IEC 60034-1 and relevant mechanical industry standards.
Five standard protection classes are available: IP23, IP44, IP54, IP55 and IP56, conforming to GB4942.1 and IEC 60034-5. IP23 motors can be modified to IP44 (pipe ventilation type) or IPW24 (weather protected type). Custom protection classes are available upon request.
Three standard cooling options are offered: IC01, IC611 and IC81W, compliant with GB/T1993 and IEC 60034-6. Alternative cooling modes can be customized as required.
The basic construction and mounting form is IMB3 (horizontal foot-mounted), meeting GB997 and IEC 60034-7 for rotating machine construction and mounting codes.
Based on rotor type, protection class and cooling system, the series is divided into 8 sub-models as shown below:
| Type | Protection Class | Cooling Method | Squirrel Cage Rotor | Wound Rotor |
|---|---|---|---|---|
| Damp Proof | IP23 | IC01 | Y Series Motor | YR Series Motor |
| Weather Protected | IPW24 | IC01 | YQF Series Motor | YRQF Series Motor |
| Air-Water Cooled Enclosed | IP44, IP54, IP55, IP56 | IC81W | YKS Series Motor | YRKS Series Motor |
| Air-Air Cooled Enclosed | IP44, IP54, IP55, IP56 | IC611 | YKK Series Motor | YRKK Series Motor |
All 10kV frame sizes listed can be adapted for 3kV, 10.5kV and 11kV versions with matched installation dimensions.
This motor drives general industrial equipment including compressors, fans, water pumps, material handling machines and conveying machinery. It serves as the prime mover widely used in mines, machinery plants, petrochemical facilities and power stations.
For heavy inertia loads such as blowers, coal mills, rolling mills, crushers and belt conveyors, customers need to submit relevant technical parameters and sign a technical agreement with us for custom design to guarantee reliable operation.
Y and YR are the base models with IP23 protection and IC01 cooling. Derivative models cover YKS, YQF, YKK, YRKS, YRQF and YRKK with different protection and cooling configurations.
The motor adopts internationally popular box-type construction. The frame and end shields are fabricated by welded steel plates, delivering high rigidity and light weight. After removing the protective cover or cooler, internal inspection and access are straightforward for installation and servicing.
The stator uses an external compression structure. Stator windings adopt Class F insulation and anti-corona materials. Winding terminals are secured by specialized reliable binding technology. The whole stator undergoes VPI vacuum pressure impregnation with solventless Class F varnish for superior insulation, moisture resistance and impulse withstand capability.
Squirrel cage rotors are mostly cast aluminium type with low risk of breakage and stable operation. Copper bar squirrel cage rotors use mature high-reliability welding and slot fixing processes. Wound rotors are fitted with Class F insulation and also treated by VPI impregnation.
Bearings are available in rolling bearing and sliding bearing types, selected according to motor power, speed and protection grade. Base bearing protection is IP44; bearing protection will be upgraded for higher enclosure classes.
Rolling bearing versions are equipped with on-line oil filling and draining fittings. Special tools support oil replenishment and discharge without motor shutdown.
The main terminal box is sealed to IP54, normally mounted on the right side facing the shaft extension. Left-side installation is available on request. Cable entry ports can be oriented upward, downward, left or right. Independent earthing terminals are fitted inside the terminal box.
Rotor thermal and pressure characteristics are calculated by professional computer simulation to prevent premature damage caused by overload during startup. Customers must comply with the following requirements:
This startup specification applies for typical quadratic torque loads such as pumps and fans.
Within the above limits, the motor allows two successive cold starts or one hot start. Restart is only permitted after full natural stop. Additional startups require a 1-hour waiting interval.
If the driven equipment inertia exceeds the listed J value, frequent startup or heavy-load startup is required, please contact our engineering team for customized design to guarantee successful starting.
Frame Size: H355-1120
Rated Voltage: 3kV, 3.3kV, 5.5kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV
Poles: 2P, 4P, 6P, 8P, 10P, 12P, 14P, 16P
Protection Degree: IP23, IPW24
Mounting Types: IMB3, IMB35, IMB5, IMV1 etc.
Power Range: Up to 25000kW
Frequency: 50Hz, 60Hz
Cooling Method: IC01
CCC, CE
Standard seaworthy export packaging
Plywood case or heat-treated fumigated wooden case
Suitable for long-distance sea transportation
All test instruments and gauges are calibrated annually. Full-process quality control covers every component:
| Component | Inspection Items |
|---|---|
| Coil | 1. Raw material physical & chemical test2. Winding process audit3. Winding dimension check |
| Iron Core | 1. Silicon steel sheet material test report2. Lamination burr and varnish film inspection3. Lamination dimension verification |
| Frame | 1. Welded component conformity certificate2. Finish machining inspection |
| Rotor | 1. Core stacking inspection2. Conductor bar welding check3. Conductor bar & end ring material, appearance, conductivity and dimension inspection4. Slot bar fastening check5. Overall dimension including core outer diameter6. Dynamic balancing correction |
| Shaft | 1. Raw material and annealing inspection2. Finish machining inspection |
| Stator | 1. Core compaction check2. Core length and segment length check3. Winding insertion inspection4. Iron loss test |
| Assembly | 1. Plain bearing dimension and surface quality check2. Air gap, stator-rotor axial alignment, internal fan and wind shield clearance check3. Internal cleaning inspection4. Shaft center height and installation dimension check |
| Final Test | 1. Routine test2. Type test |
Winding three-phase DC resistance
Winding insulation resistance to earth
Winding high voltage withstand test
No-load current
No-load power
No-load loss
Three-phase no-load current unbalance
Locked rotor current
Locked rotor torque
Maximum torque
Rotation direction
Vibration (horizontal, vertical, axial)
Noise
Full load input power
Full load current
Stator winding loss
Rotor winding loss
Iron loss
Mechanical loss
Stray loss
Full load slip
Stator winding temperature rise
Bearing temperature
Hot insulation resistance of winding
Overload test
Full load power factor
Efficiency
Standard warranty: 12 months after commissioning or 18 months after delivery, whichever occurs first.
Extended warranty is available upon request. Please contact our sales team for details.