High Efficiency & Energy Saving: Optimized electromagnetic design paired with low-loss silicon steel sheets delivers high operational efficiency and cuts power consumption.
Wide Voltage Selection: Rated voltages cover 3.3kV, 6kV, 6.6kV, 10kV, 11kV and 13.8kV to match diverse industrial working conditions.
Multiple Protection Classes: Available protection grades include IP23, IP44, IP54, IP55, IP56 and IPW24, with customized configurations supported.
Versatile Cooling Options: Cooling modes IC01, IC611 and IC81W are optional, including air-to-air cooling and air-to-water cooling structures.
Authoritative Certifications: Compliant with ISO9001, CCC, CE, GB755 and IEC34-1 standards.
Robust Structure: Welded steel frame and VPI-processed windings provide superior insulation strength and moisture resistance.
Flexible Mounting Forms: Support IMB3, IMB35, IMB5 and IMV1 installation types; terminal box position can be adjusted on request.
Proven Reliability: More than 30 years of R&D and manufacturing experience, products exported to over 40 countries and regions.
| Item | Specification | Item | Specification |
|---|---|---|---|
| Customization | Available | Application | General Industrial Use |
| Operating Speed | Constant Speed | Model NO. | Y355-4-250KW |
| Phase | Three-Phase | Series | Y, Y2 Series Three-Phase Motor |
| Rotor Type | Squirrel-Cage | Enclosure Type | Open Type |
| Pole Number | 2P–16P | Starting Method | Direct-On-Line Starting |
| Certification | ISO9001, CCC, CE | Brand | Changli |
| Rated Power | Up to 250000kW | Frequency | 50Hz, 60Hz |
| Rated Voltage | 3.3kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV | Frame Size | 315–1120mm |
| Cooling Method | IC01 | Mounting Code | IM1001 |
| Rotation Direction | CW / CCW | Duty Cycle | S1 Continuous Duty |
| Insulation Class | F | Protection Grade | IP23 |
| Ambient Temperature | -20℃ ~ 40℃ | Installation Location | Indoor / Outdoor |
| Bearing Brand | SKF | Space Heater | Equipped |
| Export Packing | Standard Seaworthy Packing | Trademark | CHANGLI |
| Origin | China | HS Code | 8501530090 |
| Production Capacity | 500000 Sets Per Year | - | - |
The Y series high voltage three-phase squirrel cage induction motor was initially developed and launched by our company in the 1980s, with over 30 years of iteration and upgrading. Benefiting from upgraded insulation materials, low-loss silicon steel laminations, enhanced protection grades and continuous design optimization, the motor reduces various internal losses and improves power density. Drawing on our 60 years of experience in high voltage motor design and production, we have completed the latest round of optimization to satisfy domestic and industrial market demands. Performance tests verify that this series reaches or approaches international advanced levels in both technical and economic indicators. Mass production has been realized, and motors are widely supplied across China and exported to more than 40 countries and regions including Europe, America and Africa, earning consistent positive feedback from end users.
Manufactured with premium raw materials and mature production processes, this motor features high efficiency, low vibration, stable operation and easy installation and maintenance.
Its power ratings, electrical characteristics, mounting dimensions and tolerances conform to GB755, IEC 60034-1 and relevant machinery industry standards.
In accordance with GB4942.1 and IEC 60034-5, available enclosure protection grades cover IP23, IP44, IP54, IP55 and IP56. IP23 units can be converted to IP44 (pipe ventilation type) or IPW24 (weatherproof type). Custom protection grades are available upon request.
Cooling modes follow GB/T1993 and IEC 60034-6, including IC01, IC611 and IC81W. Alternative cooling solutions can be customized for special requirements.
The standard construction and mounting arrangement is IMB3 (horizontal foot-mounted), complying with GB997 and IEC 60034-7.
Based on rotor type, protection class and cooling method, the product family is divided into sub-series as listed below:
| Model Group | Protection Class | Cooling Method | Squirrel Cage Rotor | Wound Rotor |
|---|---|---|---|---|
| Damp Proof Type | IP23 | IC01 | Y Series | YR Series |
| Weatherproof Type | IPW24 | IC01 | YQF Series | YRQF Series |
| Air-Water Cooled Enclosed | IP44, IP54, IP55, IP56 | IC81W | YKS Series | YRKS Series |
| Air-Air Cooled Enclosed | IP44, IP54, IP55, IP56 | IC611 | YKK Series | YRKK Series |
Technical data and installation dimensions of 10kV motors can be adapted for 3kV, 10.5kV and 11kV versions across all frame sizes.
This high voltage motor is widely used to drive compressors, fans, water pumps, mills, conveyors and other general machinery. It serves as the prime mover for mines, machinery plants, petrochemical facilities, power stations and other industrial and mining enterprises.
For heavy inertia loads such as blowers, coal pulverizers, rolling mills, crushers and belt conveyors, customers need to provide complete technical data and sign a technical agreement with us before ordering. This ensures customized design and reliable operation.
Y and YR are the base series with IP23 protection and IC01 cooling. Derivative models include YKS (air-water cooled), YQF (weatherproof), YKK (air-air cooled), YRKS, YRQF and YRKK.
Adopting the popular box-type structure, the frame and end shields are fabricated by steel plate welding for high rigidity and light weight. After removing the protective cover or cooler, internal inspection and maintenance can be performed conveniently.
The stator adopts external core pressing structure. Stator windings use Class F insulation and corona-resistant materials, with reliable special binding for winding terminals. The entire stator undergoes Class F solventless VPI vacuum pressure impregnation treatment, delivering outstanding insulation, moisture resistance and impulse withstand capability.
Squirrel cage rotors are mostly cast aluminum type with proven reliability and low failure risk. Copper bar squirrel cage rotors adopt advanced welding technology and secure slot fixation. Wound rotors also apply Class F insulation and VPI treatment.
Two bearing configurations are optional: rolling bearing and sliding bearing, selected according to motor power and speed. The base bearing protection grade is IP44 and will be upgraded accordingly for higher motor enclosure protection.
Rolling bearing versions are fitted with on-line grease filling and draining ports for maintenance without shutdown.
The main terminal box is sealed at IP54 protection. It is mounted on the non-drive side (right side viewing from shaft extension) as standard and can be moved to the left side as requested. Cable entry direction can be adjusted to top, bottom, left or right. An independent grounding terminal is built inside the box.
Finite element thermal and stress simulation is applied to squirrel cage rotors during design to avoid premature damage caused by overheating during startup. Customers shall comply with the following requirements:
Under above conditions, the motor allows two consecutive cold starts or one hot start, with natural coast-down interval between starts. Additional restart attempts are permitted after a one-hour cooling period.
If the load inertia exceeds the listed limit, frequent startup or heavy-load startup is required, please contact our engineering team for customized design confirmation.
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Frame Size: H355–1120
Rated Voltage: 3kV, 3.3kV, 5.5kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV
Poles: 2P,4P,6P,8P,10P,12P,14P,16P
Protection Grade: IP23, IPW24
Mounting Arrangement: IMB3, IMB35, IMB5, IMV1 etc.
Power Range: Up to 25000kW
Frequency: 50Hz, 60Hz
Cooling Method: IC01
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Y Series Three Phase High Voltage Squirrel Cage Induction Motor 250kW 6kV 10kV
Standard seaworthy export packing
Plywood case or fumigated wooden case
Suitable for long-distance sea transportation
All measuring instruments are calibrated annually. Every component and process is inspected strictly.
| Component | Inspection Items |
|---|---|
| Coil | 1. Raw material physical & chemical test2. Winding process patrol inspection3. Winding dimension check |
| Iron Core | 1. Silicon steel sheet material test report2. Lamination burr and insulation coating inspection3. Stack dimension verification |
| Frame | 1. Welded component conformity certification2. Finishing dimension inspection |
| Rotor | 1. Core stacking inspection2. Conducting bar welding inspection3. Rotor bar & end ring material, appearance, conductivity and dimension check4. Slot bar fastening inspection5. Outer diameter and overall dimension check6. Dynamic balance correction |
| Shaft | 1. Raw material and annealing verification2. Finishing inspection |
| Stator | 1. Core compression tightness check2. Core length and sectional dimension check3. Winding insertion inspection4. Iron loss test |
| Assembly | 1. Plain bearing dimension and surface quality check2. Air gap, stator-rotor alignment, fan and shroud clearance check3. Internal cleaning inspection4. Shaft center height and mounting dimension check |
| Final Test | 1. Routine test2. Type test |
Every motor must complete factory acceptance testing before shipment. A formal test report will be issued for qualified units.
Winding three-phase DC resistance
Winding insulation resistance to earth
Winding high voltage withstand test
No-load current
No-load power
No-load loss
Three-phase no-load current unbalance
Locked rotor current
Locked rotor torque
Maximum torque
Rotation direction
Vibration (horizontal, vertical, axial)
Noise
Full-load input power
Full-load current
Stator winding loss
Rotor winding loss
Iron loss
Mechanical loss
Stray loss
Full-load slip
Stator winding temperature rise
Bearing temperature
Hot insulation resistance
Overload test
Full-load power factor
Efficiency
Standard warranty: 12 months after commissioning or 18 months after delivery, whichever comes first.