1120kW High Voltage Squirrel Cage Asynchronous Motor for Fan Application


                    
Category :

Basic Info

ItemSpecificationItemSpecification
Model NO.Y500-4-1120KWVoltage3.3kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV
Frame Size315-1120mmCooling MethodIC01
MountingIM1001Rotation DirectionCW/CCW
Duty TypeS1Insulation ClassF
Enclosure ProtectionIP23Ambient Temperature-20℃ ~ 40℃
Installation SiteIndoor / OutdoorBearing BrandSKF
Space HeaterAvailableTransport PackageStandard Seaworthy Packing
TrademarkCHANGLIOriginChina
HS Code8501530090Production Capacity500000 units/year

Product Description

1. Product Overview

Our Y series high voltage three-phase induction motor was initially developed and launched in the 1980s. Drawing on more than 30 years of iteration and over 60 years of accumulated experience in high voltage induction motor design and manufacturing, we have repeatedly optimized the design to match domestic and industrial market demands.

Upgraded insulation materials, low-loss silicon steel sheets and structural optimization effectively cut motor losses and boost power density. Verified by type tests, this series reaches or approaches world-class standards in both technical and economic performance. Mass production has been realized, with products exported to more than 40 countries and regions across Europe, America, Africa, as well as domestic markets, earning consistent positive feedback from end users.

Manufactured with premium raw materials and mature production processes, these motors feature high efficiency, energy saving, low vibration, stable operation and easy installation & maintenance.

Power ratings, electrical characteristics, mounting dimensions and tolerances comply with GB755 (Rotating Electrical Machines – Ratings and Performance), IEC 60034-1 and relevant machinery industry standards.

Multiple protection grades are available: IP23, IP44, IP54, IP55 and IP56, conforming to GB4942.1 and IEC 60034-5. IP23 units can be converted to IP44 (pipe ventilation) or IPW24 (weather-protected type). Custom protection classes can be supplied upon request.

Three standard cooling methods are offered: IC01, IC611 and IC81W, following GB/T1993 and IEC 60034-6. Alternative cooling configurations are negotiable for special requirements.

The base construction and mounting form is IMB3 (horizontal foot-mounted), compliant with GB997 and IEC 60034-7.

This family is divided into 8 sub-series by rotor type, protection class and cooling mode:

TypeProtection ClassCooling MethodSquirrel Cage RotorWound Rotor
Damp proofIP23IC01Y SeriesYR Series
Weather-protectedIPW24IC01YQF SeriesYRQF Series
Air-water cooled enclosedIP44, IP54, IP54, IP55, IP56IC81WYKS SeriesYRKS Series
Air-air cooled enclosedIP44, IP54, IP55, IP56IC611YKK SeriesYRKK Series

The technical data and installation dimensions of 10kV motors can be adapted for 3kV, 10.5kV and 11kV variants across all frame sizes.

2. Application

This high voltage motor is widely used to drive compressors, ventilation fans, water pumps, scrapers, conveyors and other general machinery. It serves as the prime mover for mines, machinery plants, petrochemical facilities, power plants and other industrial and mining sites.

For loads with large inertia such as blowers, coal mills, rolling mills, crushers and belt conveyors, customers shall provide complete technical data and sign a technical agreement before order confirmation for customized design to guarantee reliable operation.

Standard Operating Conditions

  1. Altitude ≤1000 m
  2. Maximum ambient temperature ≤40℃; minimum ambient temperature: -15℃ for rolling bearing motors, 5℃ for sliding bearing motors; YKS / YRKS minimum ambient temperature: 5℃
  3. Cooling water inlet temperature for YKS / YRKS: 5℃ ~ 33℃
  4. Monthly average maximum relative humidity ≤90% with monthly average minimum temperature ≤25℃ in humid months
  5. Power frequency: 50Hz ±1%
  6. Operating voltage deviation: within ±5% of rated voltage
  7. Duty: S1 continuous running

3. Construction Features

Y and YR are the base versions with IP23 protection and IC01 cooling. Derivative models include YKS (air-water cooling), YQF (weather-protected), YKK (air-air cooling), YRKS, YRQF and YRKK.

Adopting internationally popular box-type structure, the frame and end shields are steel plate welded for high rigidity and low weight. Removing the protective cover or cooler allows direct access for convenient inspection, installation and maintenance.

The stator adopts external clamping structure. Stator windings use Class F insulation and anti-corona materials. Terminations are secured with specialized binding techniques. The whole stator undergoes VPI vacuum pressure impregnation with solventless Class F varnish for outstanding insulation, moisture resistance and impulse withstand capability.

Squirrel cage rotors are mostly cast aluminum type with proven zero breakage risk for high reliability. Copper bar squirrel cage rotors apply advanced slot welding and fixing technology. Wound rotors are also Class F insulated and treated with VPI impregnation.

Bearings are available as rolling bearing or sliding bearing, selected according to motor power, speed and protection grade. Base bearing protection is IP44; higher motor protection grades come with upgraded bearing protection.

Rolling bearing versions are fitted with on-line oil filling and draining ports, allowing grease replenishment and discharge without shutdown using dedicated tools.

The main terminal box is sealed to IP54. It is normally mounted on the right side (viewed from shaft extension end) and can be rearranged to the left side on request. Cable entry direction can be adjusted upward, downward, left or right. An independent grounding terminal is integrated inside the box.

4. Starting Requirements for Y, YKS, YQF, YKK Induction Motors

Finite element thermal and stress simulation is performed for squirrel cage rotors to avoid premature damage caused by overheating during startup. Please comply with the following requirements:

  1. The total inertia of driven equipment (converted to motor speed) shall not exceed the allowable load inertia J listed in technical datasheets
  2. Terminal voltage during startup shall not drop below 85% of rated voltage
    This motor is suitable for torque characteristics typical for fans and pumps.

Under above conditions, the motor permits two consecutive cold starts or one hot start. Restarts must wait for full natural coast-down. Any further startup attempts require a 60-minute cooling interval.

If the load inertia exceeds the specified limit, frequent starting is required, or heavy-load startup is needed, contact our engineering team for customized design to ensure successful starting.

Product Parameters

  • Frame Size: H355-1120
  • Rated Voltage: 3kV, 3.3kV, 5.5kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV
  • Poles: 2P,4P,6P,8P,10P,12P,14P,16P
  • Protection Degree: IP23, IPW24
  • Mounting Arrangement: IMB3, IMB35, IMB5, IMV1 etc.
  • Power Range: up to 25000kW
  • Frequency: 50Hz, 60Hz
  • Cooling Method: IC01

Quality Control & Inspection

All measuring instruments are calibrated annually. Strict inspection is implemented for every component:

PartInspection Items
Coil1. Raw material physical & chemical test2. Winding process audit3. Winding dimension check
Iron Core1. Silicon steel sheet material test report2. Lamination burr & coating inspection3. Stack dimension check
Frame1. Weld qualification certificate2. Finishing dimension inspection
Rotor1. Core stacking inspection2. Rotor bar welding check3. Bar & end ring material, appearance, conductivity and dimension verification4. Bar locking inside slots5. Core outer diameter measurement6. Dynamic balancing
Shaft1. Raw material & annealing inspection2. Finishing dimension check
Stator1. Core compression check2. Core length and segment length check3. Winding insertion inspection4. Core loss test
Assembly1. Plain bearing dimension & surface quality2. Air gap, stator-rotor axial alignment, internal fan and shroud clearance3. Internal cleaning inspection4. Shaft centre height and mounting dimension verification
Test1. Routine test2. Type test

Routine Test Items

Winding three-phase DC resistance, winding insulation resistance to earth, high voltage withstand test, no-load current, no-load power, no-load loss, three-phase current unbalance, locked rotor current, locked rotor torque, maximum torque, rotation direction, vibration (horizontal / vertical / axial), noise.

Type Test Items

Full load input power, full load current, stator winding loss, rotor winding loss, iron loss, mechanical loss, stray loss, full load slip, stator winding temperature rise, bearing temperature, hot insulation resistance, overload test, full load power factor, efficiency.

Every motor is fully tested before shipment. A formal test report will be supplied with each unit after passing inspection.

Packaging & Shipping

  • Standard seaworthy export packing
  • Plywood case or fumigated wooden case
  • Suitable for long-distance sea transportation

Warranty

Standard warranty: 12 months after commissioning or 18 months after delivery, whichever comes first.
Extended warranty is available upon request. Please contact us for quotation.


0
Inquire for more cooperation or product information.
We will contact you within 1 working day, please check your email.
1120kW High Voltage Squirrel Cage Asynchronous Motor for Fan Application
Company Name
Name
Mail
Mobile phone
Message
Send

Weigao

We reply immediately
Welcome to our website. Ask us anything 🎉

Start Chat with: